[2022] H12-425_V2.0 HCIP-Data Center Facility Deployment V2.0 Real Dumps

[2022] H12-425_V2.0 HCIP-Data Center Facility Deployment V2.0 Real Dumps

Huawei HCIP-Data Center Facility Deployment certification has been updated, H12-425_V2.0 HCIP-Data Center Facility Deployment V2.0 Real Dumps are available at FreeTestShare to be your preparation materials. H12-425_V2.0 dumps give you in-depth knowledge of the HCIP-Data Center Facility Deployment V2.0 exam syllabus. This information should be obtained at the outset of your preparation because it will assist you in developing an effective study plan. Come here to achieve the most updated H12-425_V2.0 practice questions and answers for reading.

Here we prepared some free H12-425_V2.0 exam questions, you may have a try.

Page 1 of 4

1. ATS (Automatic Transfer Switch) must overflow the manual operating handle in the case of automatic mode.

2. Which of the following resources can be managed by the capacity management function of the Huawei NetEco management system? (Multiple choice)

3. The ECC800 does not support the function of sending alarm information by email.

4. NETECOL can assign operation rights to user groups, or directly assign operation rights to users.

5. APM, NR and other UPS products need to be derated at 30 degrees, and UPS5000-E does not need to be below 40 degrees.

6. In this agenda, the refrigerant has undergone the change process of high-pressure gas, high-pressure liquid, low-pressure liquid, and low-pressure gas. In the air-conditioning system, please sort the flow direction of the refrigerant. (Sorting question)

7. In the UPS5000 configuration, the power supply reliability level can not be selected.

8. UPS5000-S has the function of adjusting the number of battery cells, which avoids the replacement of the whole group caused by the failure of a single battery, and solves the problem of difficult maintenance of traditional UPS batteries. UPS5000-s supports 30-46 battery adjustable.

9. Configure the cables of the UPS. The total current carrying capacity of the cables is greater than the rated current of the UPS to meet the requirements of the project.

10. The function of the back-feed protection card is that when the energy back-feed occurs in the main circuit or the bypass, the back-feed protection card sends a drive alarm signal, and the drive trip switch (configured by the customer) is disconnected, which plays the role of back-feed protection.


 

Share this post

Leave a Reply

Your email address will not be published. Required fields are marked *